Additionally because this method only takes measurements at or near the slab s surface it has many of the same drawbacks as the cacl 2 test.
Floor measurement top of slab to top of slabs.
Most residential slabs have a layer of 6 mil poly or a similar thicker vapor barrier membrane directly under the slab.
No surface test tells an installer how much moisture is present deeper within the concrete which is critically important as that moisture gradient will equalize if a non permeable floor covering is installed.
If they bead up on top of the slab it is probably contaminated.
Because concrete likes water the drops should absorb into the slab.
Several types of vinyl flooring may work better for different concrete floors.
We aim to reduce the weight of the slabs to bring down costs reduce transport loads and craneage where possible.
Floor flatness tends to be very important for spaces where equipment must be set perfectly.
Top of slab above i e.
These factors can introduce a lot of moisture variability across the floor slab.
Exclude formwork intersected by slabs.
Open top of wall.
As with f l the measurements are linear and higher numbers represent a flatter floor.
For example a floor with an f f measurement of 60 is twice as flat as a floor with an f f of 30.
Did the builder forget to install poly under the slab.
A range of sizes and configurations are possible with wide slabs so our designers ensure that each project is individually designed for application and loadings.
Who installed your radiant floor slab.
Slab measured across wall.
Wall measured through slab.
Even if the builder forgot to install poly under the slab there.
Do not exclude formwork intersected by beam ends.
The calcium chloride test or mver has been shown to measure moisture conditions in the top inches of the slab only.
This vinyl type comes in a single sheet that is installed over the concrete floor.
Astm f2170 rh testing inside the concrete slab the in situ rh test provides a numeric measurement of the moisture within a concrete slab using an rh sensor placed at a specific depth.
Soffit of transfer structure slab or beam above.
To test for an incompatible product on the slab an easy method is to put a few drops of water on the slab.
F f numbers can be taken for slabs on grade as well as elevated slabs.
A vinyl sheet may be forgiving if your concrete slab isn t perfectly even.
Adhering to the astm standard and installing rh sensors every 1 000 square feet is the only way to go to ensure greatest testing reliability.
This includes backing top design and protective layers.
Felts understands that one dry spot in the slab doesn t mean it is ready for the finished floor.