Receptor installation comm 82 33 8 8 a d.
Floor sinks require ready access.
This means those in a wheelchair can reach and use the sink comfortably.
Toe space enough space must exist under the plumbing pipes for the toes to extend in at least 11 inches from the front of the sink.
Space for parallel approach required at sinks 7 5.
Indirect waste piping comm 82 33 1 b e.
Access to the drain is required and when the drain is in the wall or above floor a pump type dishwasher is required.
This means a sink should not be more than 34 inches off the finished floor according to the continuing education center.
Indirect waste piping materials comm 82 33 2.
Ready access shall be provided to waste receptors.
Clear floor space at elements.
The use of fittings such as increasing couplings as a waste receptor should be avoided.
Ccr sections 11b 306 2 3 exception 1 and 11b 606 2.
All waste receptors are required to be approved by the code official.
The floor drain shall be constructed so that the drain is capable of being cleaned.
They are rarely sized appropriately and do not fit the code description of a waste receptor.
Sink knee clearances and accessible space requirements.
Clear floor or ground space 305 sufficient clear floor or ground space is required at accessible controls operable parts drinking fountains lavatories and sinks atms and fare machines appliances beds and other elements.
The ipc does require trap primers on floor drains.
Floor drains shall have waste outlets not less than 2 inches 51 mm in diameter and shall be provided with a removable strainer.
The top of the drain which receives.
Trap seal protection is not required in garage floor drains in one two and three family dwellings.
The clear floor space may extend up to 19 inches into the knee space underneath the sink.
The ada requires any sink in a public place to be accessible to those in wheelchairs.
They used to.
The plumbing system consist of a network of floor drains and one sink all in the mechanical room.
Faucets usually are placed at the center of or within six inches of the center of the sink regardless of the number of basins.
Since the clear floor space is centered on the sink users are still afforded access to faucet controls.
Trap seals of emergency floor drain traps and trap seals subject to evaporation shall be protected by one of the methods in sections 1002 4 1 1 through 1002 4 1 4.
Provisions for these elements apply the clear floor or ground specifications in 305.
Ready access shall be provided to the drain inlet.
The clear floor spaces are required at sinks and shall adjoin or overlap an accessible path of travel in the restroom.
Floor sink installation comm 82 33 8 a b c.